Guide · Updated

48V, 60V or 72V? Choosing the System Voltage for Electric Cargo Tricycles

Last checked: November 2026. General guidance for dealers, not an engineering certificate. The voltage, battery, controller and charger of the exact version you order are confirmed on the quote / proforma invoice.

In short: voltage alone does not make a tricycle stronger or faster. What matters for a dealer is (1) battery energy in watt-hours (volts × amp-hours), which sets range, (2) current, which drops as voltage rises for the same motor power and means less heat in cables and controller, and (3) parts and chargers, which must all match one voltage. Most of our cargo models, including the C16, are listed with a 60/72 V system; 48 V appears only on lighter passenger versions. Pick one voltage family per market, stock chargers and controllers for it, and compare quotes in Wh, not Ah.

1. What voltage actually changes

Electric power is voltage multiplied by current (P = V × I; see HyperPhysics, electric power). For the same motor power, a higher voltage needs less current:

Motor powerCurrent at 48 Vat 60 Vat 72 V
1,200 W (C16 rating on our site)25 A20 Aabout 16.7 A
1,500 W (C18)about 31 A25 Aabout 20.8 A

(Simple division of rated power by nominal voltage. Real current varies with load, hills and controller settings, and peaks are higher.)

Heat lost in wires and connectors grows with the square of the current (P = I²R; HyperPhysics, power and resistance). So at the same power and the same wiring, going from 60 V to 72 V cuts current by about 17% and resistive loss by about 31%. That is the honest advantage of a higher-voltage system: less current, less heat, and more headroom for heavy loads and long climbs.

What voltage does not tell you on its own:

  • Top speed. Speed comes from the motor winding, controller and rear-axle gearing together. Compare the quoted top speed, not the voltage. On our site, the C16 60 V 1,200 W version is listed at 35 km/h, and the C18 72 V 80 Ah version at 40 km/h.
  • Pulling power on hills. This depends on the motor, controller current limit and gear ratio. Ask for the specific version rather than assuming "72 V climbs better".

2. Range: compare watt-hours, not amp-hours

A battery's stored energy is roughly nominal voltage × amp-hours = watt-hours (Wh). Two quotes that both say "58 Ah" are not equal if one is 60 V and the other 72 V.

Examples from our listed specifications:

Listed batteryApprox. energy
C16 60 V 45 Ah2.7 kWh
C16 60 V 58 Ah3.5 kWh
C16 version B, 60 V 80 Ah4.8 kWh
C18 version B, 72 V 80 Ah5.8 kWh

(Nominal arithmetic only; usable energy depends on battery chemistry, age, temperature and depth of discharge.)

Range figures on our site (for example 50–80 km for the C16 and 90–100 km for the 60 V 80 Ah version) are indicative. Load, road, tyre pressure and driving style change them a lot, so tell customers a range band, not a single number.

3. Batteries, chargers and cell counts

A nominal system voltage is built from cells in series:

  • Lead-acid: each cell is about 2 V nominal, and a 12 V block has six cells (Battery University BU-205). So a 48 V pack is four 12 V blocks, 60 V is five, and 72 V is six. This matters for after-sales: customers replace whole blocks, and 12 V blocks are easy to find in most markets.
  • Lithium iron phosphate (LFP): about 3.2 V nominal per cell, charged to 3.65 V (BU-205; BU-409). Cell count and the battery management system (BMS) are set by the pack maker, so a "60 V" lithium pack must be paired with its own charger.

Charge voltage is higher than the label. Lead-acid is charged to about 2.30–2.45 V per cell (BU-403). For a 60 V lead-acid pack (30 cells) that is roughly 69–73.5 V at the end of charge; for 72 V (36 cells), roughly 83–88 V. Chargers are not interchangeable between voltages or between chemistries: never charge a 60 V pack with a 72 V charger, and never use a lead-acid charger on lithium (BU-409). For a deeper comparison, see our lead-acid vs lithium guide.

4. The 60 V line in vehicle regulations

If you sell into markets that apply UN vehicle regulations (for example the EU), note that UN Regulation No. 136 (electric power train of L-category vehicles) classifies a circuit as "high voltage" when its working voltage is above 60 V DC (up to 1,500 V DC). "Working voltage" is the highest voltage the manufacturer specifies for the circuit, in open-circuit or normal operating conditions, which includes charging (UN R136, para. 2.24; EU publication of R136).

Because charge voltage is above nominal (section 3), a pack labelled "60 V" can exceed 60 V when full. Whether a given vehicle falls under the high-voltage requirements, and how it is approved, is decided in the type-approval file, not by the label. If you sell in Europe, ask about our CE15 EEC-version and have your homologation contact confirm the details. Most of our target markets in Africa, Latin America and Asia do not use R136 for tricycle registration; check your local rules.

5. How dealers usually decide

  • Light loads, short flat routes, lowest price: 48 V or 60 V lead-acid versions. On our range, 48 V appears on the P3 (48/60 V version) and the T4 taxi (48–60 V); like our other passenger models, both are quoted with an LFP (LiFePO4) pack by default, not lead-acid.
  • General cargo, mixed roads, the safest first order: 60 V, as on the C16 standard listing.
  • Heavy loads, hills, long daily routes: 72 V versions of the C18 or the C20H (listed at 72 V).
  • One voltage per market. Mixing 60 V and 72 V vehicles doubles the chargers, controllers and battery blocks you need on the shelf. If you do mix, label every charger and keep separate spares.

For a first-order spare-parts checklist matched to one voltage, see our spare-parts checklist.

Whatever you choose, ask us to state voltage, battery chemistry and capacity, controller rating and charger in writing on the quote.

Frequently asked questions

Is a 72V electric tricycle faster than a 60V one?

Not automatically. Top speed depends on motor winding, controller and gearing. On our site the C16 60 V version is listed at 35 km/h and the C18 72 V 80 Ah version at 40 km/h. Compare the quoted speed.

Does a higher voltage give more range?

Only if it stores more energy. Compare watt-hours (volts × amp-hours): a 60 V 80 Ah pack is about 4.8 kWh, a 72 V 80 Ah pack about 5.8 kWh.

Can I use a 60V charger on a 72V tricycle?

No. Chargers must match the pack's voltage and chemistry. Lead-acid packs are charged to about 2.30–2.45 V per cell (Battery University BU-403), so a 72 V lead-acid pack ends charge around 83–88 V.

Why do some regulations treat 72V differently from 48V?

UN Regulation No. 136 classifies circuits with a working voltage above 60 V DC as high voltage, with extra protection requirements. A fully charged 60 V or 72 V pack exceeds 60 V; a 48 V lead-acid pack stays below it.

Which voltage should a new dealer start with?

For general cargo work, a 60 V version such as the C16 is the common starting point. Move to 72 V for heavy loads and hilly routes, and keep to one voltage per market where possible.

Sources

  • HyperPhysics (Georgia State University), Electric power (P = VI, P = I²R). Checked November 2026.
  • Battery University BU-205 (types of lithium-ion; lead-acid and LFP cell voltages), BU-403 (charging lead acid; 2.30–2.45 V/cell), BU-409 (charging lithium-ion; LFP 3.20 V nominal, 3.65 V charge; charger compatibility). Checked November 2026.
  • UNECE, UN Regulation No. 136, Rev. 1, para. 2.24 "High Voltage"; EU publication of R136 (OJ L 176, 2019), "Working voltage" definition. Checked November 2026.
  • Trikevia model pages (C16, C18, C20H, CE15, P3, T4) for listed specifications. Checked November 2026.

More guides

Planning your first or next container?

Tell us your country and the models you're considering. We reply with a container plan and an EXW, FOB or CIF quotation.

WhatsApp